Product Description
Estlcam clamp adapter "M"
The new Estlcam clamp adapter offers a variety of new functions and options. For the first time, it is possible to use two motors on the Y-axis and thus have the axis aligned automatically. This eliminates the need for manual alignment or the use of gantry squaring boards.
-
Estlcam USB control with screw connections
- Attention: only compatible with Estlcam version 12.100 or higher!
- older versions require the "Classic" terminal adapter
- For power amplifiers and motors with 5V clock / direction (Step / Dir) control...
- e.g. Leadshine power amplifiers / JMC servos...
- 2 Y power amplifiers (left / right) with automatic portal alignment (autosquaring) possible...
- 8 inputs for switches, proximity sensors etc...
- 4 outputs for relays and solenoid valves...
- 4 analog inputs e.g. for temperature sensors...
- 5V PWM and 0-10V analog output for speed control...
-
Adapter power supply (24V)
- Connect the "GND" and "V+" terminals on the top right with a 24V power supply unit...
- Supplies the adapter and is also available at the remaining "V+" connections to supply other components...
-
USB connections:
-
The terminal adapter M has one USB-C connection
- 1x "USB Comp." for connection to the computer...
-
The terminal adapter M has one USB-C connection
-
1x Mini-Din socket
- For the Estlcam handwheel
-
Clock / direction signals
- GND: Ground
- X / Y (LI/RE) / Z PUL: Step signal of the axis...
- X / Y (LI/RE) / Z DIR: Direction (Dir) signal of the axis...
-
For machines with gantry drive on both sides, the Y-axis signals are available twice
- Y LI PUL and Y LI DIR for the left side...
- Y RE PUL and Y RE DIR for the right-hand side...
- If the machine has only one Y-axis motor, it does not matter whether the connections are used for the left or right side...
- +5V: +5V (for output stages with common anode)
-
8 digital inputs
- GND: Ground
- Inputs 1 to 8 are "NPN" logic switching against "GND"...
- V+: Power supply (24V)
-
4 analog inputs
- GND: Ground
- 1R / 2R : Resistance measurement 0-10kOhm (measurement against "GND")
- 3U, 4U: voltage measurement 0-10V
- V+: Power supply (24V)
-
Relay / solenoid valve outputs
- V+: Common power supply (24V) of the relays / valves
- M: Output specifically for the relay for switching the milling motor
- 1 to 4: Further outputs (max 100mA per output)
-
Frequency inverter start / stop output
- The "RUN" output is a potential-free optocoupler output for switching digital inputs of frequency inverters.
- RUN-: Negative connection
- RUN+: Positive connection
-
PWM and 0-10V speed outputs
- GND: Ground
- RPM: 0-10V analog output / calibratable
- PWM: 5V PWM signal
HC-Maschinentechnik, Amelunxenstr. 40, 48167 Münster, Nordrhein-Westfalen, Deutschland, https://www.hc-maschinentechnik.de
Responsible person according to GPSR
Hebben&Binke GbR, Amelunxenstr. 40, 48167 Münster, Nordrhein-Westfalen, Deutschland, info@hc-maschinentechnik.de